6120阵列在线更换电池导致多块硬盘故障的恢复

环境描述:6120阵列电池过期,在线更换6120电池。依次更换u2pcu1和u2pcu2电源模块上的电池,没有问题。当更换完u1pcu1电源模块上的电池并加电后,u1d08,u1d10和u1d12三块硬盘同时亮黄灯,登入6120查看,三块硬盘状态均为fault,disable。
方法/步骤
1

:/:<2>vol list                     //确认卷的做法volume            capacity raid data       standbyv0             1638.382 GB    5 u1d01-13     u1d14v1             1638.382 GB    5 u2d01-13     u2d14

2

:/:<3>volslice list                //确认lun的划分Slice         Slice Num     Start Blk     Size Blks     Capacity      Volumes0            0             0             1145332224     546.136 GB   v0          s1            1             1145332224    1145352960     546.146 GB   v0          s2            2             2290685184    1145249280     546.096 GB   v0          -             -             3435934464    4608             2.250 MB   v0          s3            3             0             1145352960     546.146 GB   v1          s4            4             1145352960    1145332224     546.136 GB   v1          s5            5             2290685184    1145249280     546.096 GB   v1          -             -             3435934464    4608             2.250 MB   v1

3

:/:<4>vol init v0 sysarea         //清空sysarea信息

4

:/:<5>vol remove v0               //删除v0卷

5

:/:<6>vol add v0 data u1d01-13 raid 5 standby u1d14     //照原卷的做法重做卷v0

6

:/:<7>sun                         //以sun登入Password: arrayservicesun: commands enabled

8

:/:<9>fru stat                    //初始化完毕后3块硬盘状态正常CTLR    STATUS   STATE       ROLE        PARTNER    TEMP------  -------  ----------  ----------  -------    ----u1ctr   ready    enabled     master      u2ctr      36u2ctr   ready    enabled     alt master  u1ctr      34 DISK    STATUS   STATE       ROLE        PORT1      PORT2      TEMP  VOLUME------  -------  ----------  ----------  ---------  ---------  ----  ------u1d01   ready    enabled     data disk   ready      ready      31    v0u1d02   ready    enabled     data disk   ready      ready      31    v0u1d03   ready    enabled     data disk   ready      ready      34    v0u1d04   ready    enabled     data disk   ready      ready      30    v0u1d05   ready    enabled     data disk   ready      ready      32    v0u1d06   ready    enabled     data disk   ready      ready      29    v0u1d07   ready    enabled     data disk   ready      ready      29    v0u1d08   ready    enabled     data disk   ready      ready      28    v0u1d09   ready    enabled     data disk   ready      ready      27    v0u1d10   ready    enabled     data disk   ready      ready      27    v0u1d11   ready    enabled     data disk   ready      ready      27    v0u1d12   ready    enabled     data disk   ready      ready      26    v0u1d13   ready    enabled     data disk   ready      ready      27    v0u1d14   ready    enabled     standby     ready      ready      27    v0u2d01   ready    enabled     data disk   ready      ready      30    v1u2d02   ready    enabled     data disk   ready      ready      29    v1u2d03   ready    enabled     data disk   ready      ready      29    v1u2d04   ready    enabled     data disk   ready      ready      29    v1u2d05   ready    enabled     data disk   ready      ready      33    v1u2d06   ready    enabled     data disk   ready      ready      28    v1u2d07   ready    enabled     data disk   ready      ready      29    v1u2d08   ready    enabled     data disk   ready      ready      27    v1u2d09   ready    enabled     data disk   ready      ready      29    v1u2d10   ready    enabled     data disk   ready      ready      26    v1u2d11   ready    enabled     data disk   ready      ready      28    v1u2d12   ready    enabled     data disk   ready      ready      24    v1u2d13   ready    enabled     data disk   ready      ready      26    v1u2d14   ready    enabled     standby     ready      ready      26    v1 LOOP    STATUS   STATE       MODE        CABLE1    HLB  CABLE2    HLB  TEMP------  -------  ----------  -------     --------- ---  --------- ---  ----u1l1    ready    enabled     master      -         -    installed 111  35u1l2    ready    enabled     slave       -         -    installed 110  39u2l1    ready    enabled     master      installed 001  -         -    35u2l2    ready    enabled     slave       installed 110  -         -    38 POWER   STATUS   STATE       SOURCE  OUTPUT  BATTERY  TEMP    FAN1    FAN2------  -------  ---------   ------  ------  -------  ------  ------  ------u1pcu1  ready    enabled     line    normal  normal   normal  normal  normalu1pcu2  ready    enabled     line    normal  normal   normal  normal  normalu2pcu1  ready    enabled     line    normal  normal   normal  normal  normalu2pcu2  ready    enabled     line    normal  normal   normal  normal  normal

9

:/:<10>volslice create s0 -z 546.136GB v0:/:<11>volslice create s1 -z 546.146GB v0:/:<12>volslice create s2 -z 546.096GB v0         //照原lun大小重新划lun

10

:/:<13>lun default all_lun rw          //设置新划lun的访问权限为rw

11

:/:<15>vol mount v0                     //挂接卷v0

12

:/:<16>vol stat v0                      //确认卷v0状态v0: mounted  u1d01: mounted  u1d02: mounted  u1d03: mounted  u1d04: mounted  u1d05: mounted  u1d06: mounted  u1d07: mounted  u1d08: mounted  u1d09: mounted  u1d10: mounted  u1d11: mounted  u1d12: mounted  u1d13: mounted  Standby: u1d14: mounted

13

主机端用fsck修复卷v0下几个lun的文件系统。修复完毕后挂接v0上的各个lun,卷v0上的数据没有丢失。