螺丝刀一套
2.5mm的内角扳手一个长度大于10cm
防静电手环
信息收集:# Location Alert Keyword Timestamp498 PDC 0,0,3 *12 0x180035c 0x0000 PDH_CELL_INFO_COREIO_UPDATE_ERR498 PDC 0,0,3 *12 0x58003d 0x00006e090f011327 10/15/2010 01:19:39497 PDC 0,0,3 *12 0x180034c 0x0000 PDH_CELL_INFO_RIO_UPDATE_ERR497 PDC 0,0,3 *12 0x58003c 0x00006e090f011301 10/15/2010 01:19:01496 PDC 0,0,3 *12 0x180033c 0x0000 PDH_CELL_INFO_COREIO_UPDATE_ERR496 PDC 0,0,3 *12 0x58003b 0x00006e090f011121 10/15/2010 01:17:33495 PDC 0,0,3 *12 0x180032c 0x0000 PDH_CELL_INFO_RIO_UPDATE_ERR495 PDC 0,0,3 *12 0x58003a 0x00006e090f011121 10/15/2010 01:17:33...MP:CM> ps...Power Status---------------+-----+-----+-------+-----+ | | | | | | Sys | | IO | | |Bkpln|Cells|Chassis| BPS | | | 0 1 | 0 1 | 0 1 |---------------+-----+-----+-------+-----| Populated | * | * * | * * | * * | Enabled | * | * | * * | * * | Power OK | * | * | * * | * * | Warning/Fault | | | | | Attention LED | | | | | |...MP:CM> cp --------+--+Cabinet |0 |--------+--+ Slot |0 1|--- ----- + --+Part 0 |* *| 判断出是cell board的问题需要更换cell board。
1.再次检查RP7410主机硬件状态,确认CELL 1位置.
2.使用串口线连接MP卡,使用PS命令检查电源状态,使用PE命令关闭机器电源。
3.记录并标记主机所有连线,移除所有连线,包括电源线。
4.戴上静电手环,将RP7410从滑轨抽出,拆开侧面板,有上下两个cell 板,上位0下为1,掰开cell 1的卡扣,将cell 1抽出,放在准备好的静电垫上。
5.将故障cell板上面的CPU和内存按故障cell板的位置转移到新cell板上,注意调整cell板上面跳线,应与故障cell板一致。
6.安装完毕后,将cell板插回,盖上侧面板,将机器按滑轨推回原来位置,还原所有连线。
7.进入MP卡,ps检查硬件状态,sysrev检查FIRMWARE信息。
8.设置网络环境,ls查看MP卡地址,配置笔记本IP为一个网段,使用ping命令检查连接,然后打开ftp服务,设置好FW文件的目录。
9.首先保证分区操作系统是关闭的,分区cell板已加电,在MP卡上CM中使用ps命令来确认
10.在MP卡的CM中使用sysrev查看cell 1的FIRMWARE信息,确认要升级的实体文件及版本:
11.为了进行firmware升级,将分区重置,保持在BIB状态,在MP卡上CM中使用rr命令。
12.先使用FW命令升级PDC和PDHC,升级完成后执行ru操作来重置PDHC,接着执行rs重置分区,使用命令sysrev检查PDC和PDHC是否升级成功,然后再rr分区回到BIB状态。
13.接着使用OSP命令升级celllpm,bob和drain,升级方法与FW相同,升级完成后,使用pe命令关闭cell 1电源,30秒后重新加电,使用sysrev命令查看升级是否成功。
14.进入MP卡,ps检查硬件状态,pe启动partition0,检查是否有硬件报错。检查硬件指示灯状态。
15.查看系统event.log及syslog.log看有没有指示其它问题。
16.一切正常,维修结束。
查看fw是否升级成功。
更换备件时候要插紧备件像内存cpu